Model 9135 Two-Port and 9140 Four-Port SNMP Managed Fast Ethernet Switch User Manual Canoga Perkins Deleted: Deleted: andDeleted: ¶
viiiThis page intentionally left blank.
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-1 FormattedDeleted: ¶¶Deleted: Page of 871
1-2Chapter 1 Quick Start Installation 1.1 Typical EdgeAccess 9135 Two-Port Switch Application The application shown in Figure 1-1 represents a ca
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-3 1.2 EdgeAccess 9135/9140 Redundant Switch Application The application shown in figur
1-41.3 Quick Start Installation of the 9135/9140 Switch The initial setup of your EdgeAccess 9135 Two-Port or 9140 Four-Port Switch (9135/9140) inv
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-5 1.4 Quick Start Interface DIP Switch Settings Although the 10/100BASE-TX UTP interf
1-61.5 Quick Start Configuration of the 9100-300 10/100BASE-TX UTP Interface Configure the UTP interface as follows: Step 1 Insert the UTP inter
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-7 1.6 Quick Start Configuration of the 9100-310 10/100BASE-TX UTP Interface Configure
1-81.7 Quick Start Configuration of the 10BASE-FL/100BASE-FX Interfaces The 9135 Two-Port and 9140 Four-Port Switch feature 10Mbps and 100Mbps fiber
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-9 1.8 Quick Start Interface Connection Caution: To protect the Ethernet port from an
1-10Step 4 Once connected, the correct operation of the local 100BASE-FX SMF interface, SMF optic cable and remote 100BASE-FX SMF interfaces can be
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-11 1.10 Quick Start PC Configuration for Terminal Operation The following explanation
1-12Step 3 Select COM1 from the Connect using drop down menu as shown in Figure 1-10 and click OK. Note: Most computers use COM2 for the serial m
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 1-13 Step 5 At this point the HyperTerminal program will open the newly created 9135/914
1-14This page is intentionally left blank.
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 2-1 Chapter 2 Overview 2.1 EdgeAccess 9135 Two-Port and 9140 Four-Port Fast Ethernet Sw
2-2• 9100-617: 100BASE-FX 1300nm SM fiber with ST Duplex connectors and 26dB optical budget • 9100-618: 100BASE-FX 1300nm SM fiber with SC Du
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-1 Chapter 3 Installation and Setup 3.1 Installation This section provides instructio
3-23.1.3 Wall Mount Installation For a Wall Mount installation, the 9135 and 9140 Four-Port Switch feature two wall mount holes located on the botto
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-3 3.2 Setup Figure 3-4. Front View of the 9135 Two-Port Switch and 9140 Four-Port S
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 i CAUTION! This product may contain a laser diode emitter operating at a wavelength of 1
3-43.2.1 9100-300 10/100BASE-TX Module This module is a plug-in, which contains the 10/100BASE-TX interface, see Figure 3-5. Caution: To protect th
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-5 3.2.2 9100-310 10/100BASE-TX Module This module is a plug-in, which contains the 10/
3-63.2.3 100BASE-FX Single Mode Module This is a plug-in module, which contains the 100BASE-FX Single Mode interface Figure 3-6. The interface comp
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-7 3.2.4 100BASE-FX Multimode Module This module is a plug-in which contains the 100BASE
3-83.2.5 10BASE FL Single Mode Module This module is a plug-in which contains the 10BASE-FL Single Mode interface Figure 3-8. The interface compone
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-9 Deleted: ¶¶¶¶¶Deleted: Page of 871
3-103.2.6 10BASE-FL Multimode Module This is a plug-in module which contains the 10BASE-FL Multimode interface Figure 3-9. The interface components
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-11 3.2.7 10BASE-5 AUI Module This contains the 10BASE-5 AUI STD DTE interface. See Figu
3-123.2.8 Relay Contacts The alarm contacts for the 9135 Two-Port Switch and the 9140 Four-Port Switch are located next to the fan assembly on the re
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-13 3.2.9 AC/DC Power and Switch The 9135 Two-Port and 9140 Four-Port Switches can be e
iiNOTICE Canoga Perkins has prepared this user manual for use by customers and Canoga Perkins personnel as a guide for the proper installation, oper
3-14 Figure 3-14. Typical DC Power Supply Connections. The polarity of the source DC supply determines the appropriate connection to the 9135/9140
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 3-15 This page is intentionally left blank. Deleted: Page of 871
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 4-1 Chapter 4 Software Management 4.1 SNMP Management Overview - VT100 The 9135 Two-Po
4-24.1.4 Front Panel Diagnostics The SNMP Manager Module diagnostics for the 9135 Two-Port and 9140 Four-Port Switch are indicated on the front pane
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 4-3 The main functions are the following: • Self-learning Bridge (Enable / Disable Lear
4-44.8 BOOTP The BOOTP function supports the loading of network parameters from a BOOTP server. The following parameters are supported: • IP addres
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-1 Chapter 5 Management Setup and Operation If you have the optional 9100-M SNMP modul
5-2 Figure 5-2. Naming the HyperTerminal Connection File Step 2 The HyperTerminal program will open and prompt you to configure the serial port fo
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-3 Figure 5-4. COM1 Properties Screen. Step 5 At this point th
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 iiiTable of Contents Chapter 1 Quick Start Installation ...
5-45.2 Operation of the VT100 Program If this is your initial setup and no password has been defined, the 9135/9140 will go directly to the Main Me
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-5 When the Main Menu screen appears, the user may select the appropriate screen to setu
5-6 Figure 5-8. IP Settings Menu. 5.2.1.1 IP Settings This screen lists all the IP settings and configurations for your management module. See Fi
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-7 • Enable BOOTP Mode: BOOTP must be enabled if the Management Module needs to obtain
5-8To modify the Host Table or SNMP Settings, select the desired number 1-8. Press the <Tab> key to scroll through each of the possible selecti
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-9 After you have selected the desired field to change, the current selection will becom
5-10 Figure 5-13. Passwords Menu. Technical notes on Password Protection: When logging on, if the password string you enter matche
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-11 MENU ITEM MINIMUM ACCESS LEVEL Host Table / SNMP Settings Menu Host tabl
5-12 MENU ITEM MINIMUM ACCESS LEVEL Diagnostics Menu Redundancy Setting SUPERVISOR Ping Menu Ping Address USER Ping Count
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-13 Figure 5-15. Redundancy Setting Screen. 5.2.1.7 Redundancy (Back
iv5.2 Operation of the VT100 Program... 5-4 5.2.1 Syste
5-14Situation One: Port 2 Link Active / Port 1 Link Inactive / No Failures Under normal operating conditions link one shows disabled because the Par
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-15 5.2.2 Switch Configuration To set up the Switch configuration, select number 2 from
5-16 ACEBD123456A small test networkACEBD123456Spanning Tree from source (C) Figure 5-19. Graphical Depiction of a Spanning Tree Application. Wh
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-17 Figure 5-20. Spanning Tree Parameters. 5.2.2.2 Global Spanning Tree To enable t
5-18 Figure 5-21. Global Spanning Tree Parameters Menu. Port Spanning Tree Parameters can be viewed from the Port Spanning Tree sc
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-19 Figure 5-22. Port Spanning Tree Parameters. 5.2.2.5 Spanning Tre
5-20 Figure 5-23. Spanning Tree Report Screen. 5.2.2.6 VLAN Configuration Note: The 9135 Two-Port Switch does not support the V
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-21 Figure 5-25. VLAN Configuration Screen. To configure the VLAN p
5-225.2.3 Port Information The Port Information screen shows the individual or accumulative status of each of the 9135/9140 Ports. There is a graphi
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-23 5.2.4 Reports The Reports Menu gives the user access to a brief unit description, a
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 v List of Figures Figure 1-1. Typical 9135 10/100Mbps UTP/Fiber Application...
5-24Number of Traps logged. 5.2.4.2 Traps Log Screen The Traps that can be reported are predefined and are not configurable as far as what traps can
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-25 5.2.5 Diagnostics The Diagnostics menu allows the user to perform Ping and Sniffer
5-265.2.5.2 Sniffer Settings (9140 Four-Port Switch) One of the Ports on the 9140 can be assigned as a sniffer port. When this option is selected,
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-27 Figure 5-35. Restore Defaults, Restart Unit and Logout from Main Menu.
5-28 Step 7 One Software Revision Flash is active while the other simply holds the other version until it is invoked. This is evident because each
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 5-29 7. Start the FTP Client (for details, see the documentation for the client softwar
5-30This page is intentionally left blank.
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 6-1 Chapter 6 Specifications 6.1 Interfaces Number of Ports: • Two on Model 9135, plu
6-2100Mbps Fiber Multimode: • 100BASE-FX • ST and SC connectors • Full / Half-duplex configurable • Optical budget: minimum 11dB for 62.5/125 mi
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 6-3 6.2 Switching Characteristics Technology: ASIC based parallel Store and Forward
viFigure 5-23. Spanning Tree Report Screen. ... 5-20 Figure
6-46.3 Indicators Port: 100BASE-TX: Transmit (Tx) Link (Lnk) Collision (Col) Half / Full-duplex (Fdx) Receive (Rx) Auto (Aut)
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 6-5 6.5 Physical / Environmental Dimensions: 17.25"W x 13.375"L x 1.75&qu
6-6 This page is intentionally left blank.
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 A-1 Appendix A Default Values Agent IP address unchanged Agent Netmask 255.255.
A-2 This page is intentionally left blank.
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 B-1Appendix B SLIP Instructions B.1 EdgeAccess Application with SNMP via SLIP The 913
B-2B.2 Configuring the 9135 or 9140 for SLIP Connect a DCE to DTE serial modem cable between the 9135 or 9140 Switch and the PC or terminal. Perfo
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 B-3 Verify the following settings: 1. Interface: modem 2. Init Modem At Startup: Yes
B-4 Figure B-4a. Modem Properties. Step 3 Confirm that the modem's maximum speed is set as per the modem operator's manual (e.g. 9600 ba
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 B-5Step 4 Set the dialing properties of the modem as shown in Figure B-5, adjusting the
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 viiCanoga Perkins EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135 Two-Por
B-6Step 6 Click the "New" tab. Figure B-7. Dial-Up Networking Screen. Under "Basic" tab, designate a name for the connection
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 B-7Select "Server" tab. Under "Dial-Up Server Type," highlight "
B-8Note: The SLIP IP address should be on a different subnet from your LAN or any other network interface using TCP/IP Stack. Verify that "For
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 B-9 Figure B-13. Confirm SLIP Connection. Step 9 The Ping Program in MSDOS will norm
B-10 In the "Connect" drop-down menu, select "Remote System." The "Connect" screen will appear as shown in figure B-1
EdgeAccess SNMP Managed Fast Ethernet Switch Model 9135/9140 C-1Appendix C Acronyms / Abbreviations AC = Alternating Current API = Application
C-2MIB = Management Information Base MMF = Multimode Fiber NEBS = Network Equipment Building Standards nm = nanometer (1 billionth of
Appendix D Limited Warranty Limited Lifetime Warranty Effective July 1, 2005 and After, Canoga Perkins warrants that, at the time of sale, and, fo
D-2Limitations Canoga Perkins may at its sole discretion modify its Limited Warranty at any time and from time to time. Other than those expressly st
CANOGA PERKINS CORPORATION Customer Service Department 20600 Prairie Street Chatsworth, California 91311-6008 USA Business Phone: (818) 718-6300
Comentarios a estos manuales