Canoga-perkins 1502 Domain Management Module Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware De La Computadora Canoga-perkins 1502 Domain Management Module. CANOGA PERKINS 1502 Domain Management Module User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - User Manual

EdgeAccess Universal Chassis System Model 1502 Domain Management Module User Manual

Pagina 2

EdgeAccess Universal Chassis System Front Panel Functions The DMM front panel includes these features (see Figure 2): • Four Status LEDs; Table 1 lis

Pagina 3 - Table of Contents

EdgeAccess Universal Chassis System Chapter 3 Software Management Through VT100 You can manage the system with VT100 Terminal Emulation through the c

Pagina 4 - List of Tables

EdgeAccess Universal Chassis System Management User Interface The Management User Interface for the DMM provides screens for setup, monitoring, and di

Pagina 5 - Chapter 1

EdgeAccess Universal Chassis System User Interface Organization The user interface consists of selectable, nested menus and screens, available in this

Pagina 6

EdgeAccess Universal Chassis System Login and DMM Main Menu When you connect to the DMM through HyperTerminal or Telnet, the first screen is the DMM L

Pagina 7 - DMM Management and SBMC

EdgeAccess Universal Chassis System Manage the DMM The DMM provides communication with and some controls of the various chassis and modules within the

Pagina 8 - Security

EdgeAccess Universal Chassis System Table 4. System Configuration Report Item Description Chassis Type Always 2U, the UCS 1002 Ethernet Address MAC

Pagina 9 - Chapter 2

EdgeAccess Universal Chassis System Table 6. IP Address Classes Class First Octet of IP Address Default Subnet MaskClass A 1-126 255.0.0.0 Class

Pagina 10 - Front Panel Functions

EdgeAccess Universal Chassis System Table 7. Trap Configuration Options Trap When enabled, sends a Trap if. . . Cold Start The DMM is reset by a po

Pagina 11 - Chapter 3

EdgeAccess Universal Chassis System • Enter the values for primary and alternate SNTP servers: • IP Address: Set the address for the server; 0.0.0.

Pagina 12 - General Screen Format

EdgeAccess Universal Chassis System NOTICE Canoga Perkins has prepared this users manual for use by customers and Canoga Perkins personnel as a guide

Pagina 13 - User Interface Organization

EdgeAccess Universal Chassis System Test a Connection With PING When you set up a new connection or need to troubleshoot an existing connection to ano

Pagina 14 - Login and DMM Main Menu

EdgeAccess Universal Chassis System Use the Software Upgrade report and menu screen to check the current version of the DMM firmware and to upgrade so

Pagina 15 - Manage the DMM

EdgeAccess Universal Chassis System 9. If this is new firmware for another module in the domain, follow these steps when the file transfer is complet

Pagina 16

EdgeAccess Universal Chassis System 3. At the Security Configuration screen, type the number for an item and press <Enter>, then type a value o

Pagina 17 - Manage Traps and Alarms

EdgeAccess Universal Chassis System 3. To add a user, type 1, or to edit an existing user, type 3, and press <Enter>, then type the Username an

Pagina 18 - Manage the Date and Time

EdgeAccess Universal Chassis System Set Up Host Access The SNMP agent allows access to up to 24 Host IP addresses listed in the Host Access Table. Se

Pagina 19

EdgeAccess Universal Chassis System Use the Radius Client Configuration screen to set up communication with the Radius server in order to authenticate

Pagina 20 - Update Software

EdgeAccess Universal Chassis System Set Up the Notification Destination for Traps Use the Trap Notification/Destination Table to view and set up the d

Pagina 21

EdgeAccess Universal Chassis System • Authentication Key: Shows the key that authenticates the notification for MD5 or SHA Authentication Protocol;

Pagina 22 - Manage Security

EdgeAccess Universal Chassis System To view the System Log screen, follow these steps: 1. From the Main Menu, type 7, "Alarm/System Log," a

Pagina 23

EdgeAccess Universal Chassis System Table of Contents Chapter 1 Overview and Management Architecture...1-1 F

Pagina 24

EdgeAccess Universal Chassis System Table 8. Syslog Message Severity Mask Levels Severity Level Include Message Types About...and Higher Example Mes

Pagina 25 - Set Up a Radius Client

EdgeAccess Universal Chassis System Manage the Module Code Library The Module Code Library, located in the Flash Memory so that the information remain

Pagina 26 - Change Your Password

EdgeAccess Universal Chassis System Create and Manage Virtual Groups You can set up a Virtual Group to upgrade software or swap memory banks on two or

Pagina 27

EdgeAccess Universal Chassis System Manage a Chassis You can manage the modules within a chassis. You can view information, such as type, status, sof

Pagina 28 - Manage the Domain

EdgeAccess Universal Chassis System CHASSIS MANAGEMENT Chassis:5 Bootcode Version Firmware Version S

Pagina 29 - Set Up the Syslog Client

EdgeAccess Universal Chassis System To access the CIM Management screen, follow these steps: 1. From the DMM Main Menu, type 5, or "Manage or ac

Pagina 30 - 1 and follow the prompts on

EdgeAccess Universal Chassis System To access the Module Menu, follow these steps: 1. From the DMM Main Menu, type 4, or "Manage or access a spe

Pagina 31 - Manage Logged In Users

EdgeAccess Universal Chassis System Chapter 4 Specifications Physical Specifications Dimensions 3.0"H x 1.0"W x 9.0"D (76.2 mm x 25.4

Pagina 33 - Manage a Chassis

EdgeAccess Universal Chassis System Appendix A Warranty Limited Lifetime Warranty Effective July 1, 2005 and After, Canoga Perkins warrants that, at

Pagina 34 - Manage a CIM

EdgeAccess Universal Chassis System Chapter 4 Specifications ...

Pagina 35 - Manage a Module

EdgeAccess Universal Chassis System Limitations Canoga Perkins may at its sole discretion modify its Limited Warranty at any time and from time to ti

Pagina 36

EdgeAccess Universal Chassis System Appendix B Configuration File Fields and Defaults ### WARNING - DO NOT MODIFY THIS HEADER ### CfgFileBuiltWithFir

Pagina 37 - Specifications

EdgeAccess Universal Chassis System ## Group Name <7> VirtualGroupName = ## ----- <1> VirtualGroups [ VirtualGroupChassis = VirtualGrou

Pagina 38

EdgeAccess Universal Chassis System VirtualGroupChassis = VirtualGroupSlot = VirtualGroups ] ## End Group Name <18> End ## Group Name <19&

Pagina 39 - Warranty

EdgeAccess Universal Chassis System ## Group Name <30> VirtualGroupName = ## ----- <1> VirtualGroups [ VirtualGroupChassis =2 VirtualGro

Pagina 40 - Return Policy

EdgeAccess Universal Chassis System SlotName(6) = SlotName(7) = SlotName = SlotName(1) = SlotName(2) = SlotName(3) = SlotName(4) = SlotName(5)

Pagina 41 - Appendix B

EdgeAccess Universal Chassis System SlotNameA(2) = SlotNameA(3) = SlotNameA(4) = SlotNameA(5) = SlotNameA(6) = SlotNameA(7) = SlotNameA = Slot

Pagina 42

EdgeAccess Universal Chassis System SlotNameB(6) = SlotNameB(7) = SlotNameB = SlotNameB(1) = SlotNameB(2) = SlotNameB(3) = SlotNameB(4) = Slot

Pagina 43

EdgeAccess Universal Chassis System ## ----- <1> HostTable [ HostTableIpMask = 172.16.2.58 /32 HostTableTelnetAccess = Telnet and SSH HostTable

Pagina 44

EdgeAccess Universal Chassis System Index A add host access, 3-14 trap destination, 3-16 user account, 3-13 virtual group, 3-21 alarms CIM Management

Pagina 45

EdgeAccess Universal Chassis System Chapter 1 Overview and Management Architecture The Model 1502 Domain Management Module (DMM) provides Universal C

Pagina 46

EdgeAccess Universal Chassis System M MAC address, 3-7 menu Change Security & Passwords, 3-12 DMM Main Menu, 3-4 Domain Management Module, 3-4 Mo

Pagina 47

EdgeAccess Universal Chassis System Set Date and Time screen, 3-8 set up terminal connection, 3-1 sideband management channel, 1-3 SIMM card function

Pagina 50

CANOGA PERKINS CORPORATION 20600 Prairie Street Chatsworth, California 91311-6008 USA Phone: (818) 718-6300 FAX: (818) 718-6312 Web Site: w

Pagina 51

EdgeAccess Universal Chassis System Features of the Domain Management Module The DMM, shown in Figure 2, provides these features and functions: • Com

Pagina 52

EdgeAccess Universal Chassis System DMM Management and SBMC Depending on the number and organization of modules and chassis, DMM management can includ

Pagina 53

EdgeAccess Universal Chassis System Security For enhanced security, the DMM supports four network security protocols: SNMPv3, Remote Access Dial In U

Pagina 54 - CANOGA PERKINS CORPORATION

EdgeAccess Universal Chassis System Chapter 2 Hardware Installation and Functions This section describes how to install the DMM in the UCS Model 1002

Comentarios a estos manuales

Sin comentarios