Vista de pagina 98
CanogaOS Configuration Guide
Proprietary & Confidential Canoga Perkins Metro Ethernet Switches Page 99 of 350
mode.
DUT(config-if)# ethernet oam remote-failure critical event
dying-gasp link-fault action errordisable-interface
Configure the Ethernet OAM
remote-failure action on eth-0-9.
Configure the interface to shut down
when any of the critical link events
take place on the remote machine.
DUT(config-if)# end Exit the Interface mode.
Validation
When a remote failure action (error-disable-interface) is configured in Bridge1 and when a critical link event
(link fault, dying gasp, or other critical event) occurs in Bridge2, the interface is disabled (shut down).