CanogaOS Configuration Guide
Proprietary & Confidential Canoga Perkins Metro Ethernet Switches Page 89 of 350
DUT(config-if)# switchport mode trunk Set the switching characteristics of
this interface to trunk mode.
DUT(config-if)# switchport trunk allowed vlan all Enable all VLAN IDs on this port.
DUT (config-if)# ethernet cfm mip level 5 Configure a maintenance
Intermediate point (MIP).
DUT (config-if)#ethernet cfm mep level 3 up mpid 999 vlan 30 Configure a maintenance end point
(MEP).
DUT (config-if)# no shutdown Bring up the interface.
DUT (config-if)#exit Exit the Interface mode
DUT(config)#interface eth-0-17 Specify the interface (eth-0-17)to be
configured and enter the Interface
mode
DUT(config-if)# switchport mode trunk Set the switching characteristics of
this interface to trunk mode.
DUT(config-if)# switchport trunk allowed vlan all Enable all VLAN IDs on this port.
DUT (config-if)# no shutdown Bring up the interface.
DUT (config)#ethernet cfm enable Enable CFM globally.
DUT (config)#ethernet cfm cc level 3 vlan 30 interval 10000 Configure the interval in the selected
service instance (MA) instance with
the configured domain-level.
DUT (config)#ethernet cfm cc enable level 3 vlan 30 Enable continuity check in the
selected service instance (MA)
instance with the configured
domain-level.
DUT(config-if)# end Exit the Interface mode.
Bridge4
DUT# configure terminal Enter the Configure mode.
DUT(config)# vlan database Enter the VLAN database..
DUT(config vlan)# vlan 30 Configure VLAN 30
DUT(config vlan)# exit Exit the VLAN database
DUT(config)# ethernet cfm domain customer level 5 Create a domain,
DUT (config-ether-cfm)#service cst vlan 30 Define a Maintenance Association
(MA) for the domain created.
DUT (config-ether-cfm)#exit Exit the CFM database.