CanogaOS Command Line Reference Revision 1.02
Proprietary & Confidential Canoga Pertkins Metro Ethernet Switches Page 364 of 855
18.13.1.3 Command Mode
Track mode
18.13.1.4 Defaults
Default value is 0 seconds.
18.13.1.5 Examples
In the following example, the delay up command is used to configure delay when object state is
turned from down to up:
Switch(config)#track 1
Switch(config-track)#delay up 30
18.13.1.6 Related Commands
Show track
18.14 DELAY DOWN
To specify a period of time (in seconds) to delay communicating state changes of a tracked
object, use delay down in track mode. To come back to default value, use the no form of this
command.
18.14.1.1 Command Syntax
delay down seconds
no delay down
18.14.1.2 Syntax Description
seconds
Time range is from 1 to 180.
18.14.1.3 Command Mode
Track mode
18.14.1.4 Defaults
Default value is 0 seconds.
18.14.1.5 Examples
In the following example, the delay down command is used to configure delay when object state
is turned from up to down:
Switch(config)#track 1
Switch(config-track)#delay down 30