
CanogaOS Configuration Guide
11-3
DUT# configure terminal Enter the Configure mode.
DUT (config)#ethernet cfm enable Enable CFM globally.
DUT (config)#ethernet cfm cc level 5 vlan 30 interval 10000 Configure the interval in the selected
service instance (MA) instance with the
configured domain-level.
DUT (config)#ethernet cfm cc enable level 5 vlan 30 Enable continuity check in the selected
service instance (MA) instance with the
configured domain-level.
DUT(config-if)# end Exit the Interface mode.
Bridge2
DUT# configure terminal Enter the Configure mode.
DUT(config)# vlan database Enter the VLAN database..
DUT(config vlan)# vlan 30 Configure VLAN 30
DUT(config vlan)# exit Exit the VLAN database
DUT(config)# ethernet cfm domain customer level 5 Create a domain,
DUT (config-ether-cfm)#service cst vlan 30 Define a Maintenance Association (MA)
for the domain created.
DUT (config-ether-cfm)#exit Exit the CFM database.
DUT(config)# ethernet cfm domain provider level 3 Create a domain
DUT (config-ether-cfm)#service cst vlan 30 Define a Maintenance Association (MA)
for the domain created.
DUT (config-ether-cfm)#exit Exit the CFM database.
DUT(config)#interface eth-0-9 Specify the interface (eth-0-9)to be
configured and enter the Interface mode
DUT(config-if)# switchport mode trunk Set the switching characteristics of this
interface to trunk mode.
DUT(config-if)# switchport trunk allowed vlan all Enable all VLAN IDs on this port.
DUT (config-if)# ethernet cfm mip level 5 Configure a maintenance Intermediate
point (MIP).
DUT (config-if)#ethernet cfm mep level 3 up mpid 666 vlan 30 Configure a maintenance end point
(MEP).
DUT (config-if)# no shutdown Bring up the interface.
DUT (config-if)#exit Exit the Interface mode
DUT(config)#interface eth-0-17 Specify the interface (eth-0-17)to be
configured and enter the Interface mode
Comentarios a estos manuales