Chapter 4
Initial Power
-
on & Start
-
up of Switch
4.1
Building Configuration Platform and
Connectin
g Cable:
Fig. 4
-
1: Building Local Configuration Platform Through Console Port
Step 1: Connect DB
-
9 hole
-
type plug of configuration cable to the serial port for configuring switch.
Step 2: Connect RJ
-
45 end of configuration cable to the console port of switch.
4.2
Setting Terminal Parameter
Step 1: Turn on PC and run emulator program
(
Windows system has its own
hyper terminal)
.
Step 2: Set terminal parameters (take the
hyper
terminal setting of Windows XP as an example).
Parameter requirements: baud rate: 9600, data bit: 8, parity: no, stop bit: 1, flow control: NA,
selecting termin
al emulation: VT100. Specific method is as follows:
Click "Start"
-
"Program"
-
"Attachment"
-
"Communication"
-
"
Hyper
Terminal" to
run
Hyper
T
erminal window
and establish a new connection, then a connection description interface will pop up as shown in F
ig. 4
-
2.
Fig. 4
-
2: New Connection