Power Wire and Grounding Connection
It is recommended that users use single
wire outlets with neutral point connectors or
multifunction microcomputer outlets. The neutral points of power must be grounded reliably in a building.
Generally, in wiring of building construction,
the power neutral points of electrical supply system in such
a building have been buried under the earth, so users need to confirm the power has been grounded.
Step 1: Connect one end of the
wire on enclosure included in a
screw on back panel of the switch, and the other end is
Step 2: Insert one end of the power wire of the switch into the outlet on back panel of the
cabinet, and the other end into a
n on the power switch, and check if the power indicator on front panel of the switch is
bright, which indicates that power connection is correct.
wire must be connected before switches are powered on.
r is connected on the power input of switch, whose central
the cabinet, which is called enclosure
(that is PE). This cabinet must be well grounded to
enable the safe flow of influence electricity and leakage int
o the earth and increase the
electromagnetic interference of switch.
Correct Way of Grounding is as follows:
Connect one end of the yellow and green PE cable of switch to the terminal of grounding bar and screw
up the fastening nut when there is a gr
ounding bar in the installation environment of Ethernet switches.
Note: it is an incorrect option to be grounded with fire mains and a lightning rod in a building, so the
ground wires of Ethernet switches should be connected to the works in switch room an