Canoga-perkins 9171 Command Reference Manual de usuario Pagina 721

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 782
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 720
CanogaOS Command Reference
40-50
configuration mode. To return the logging to the default level, use the no form of this command.
Command Syntax
logging level file {alert | critical | debug | emergency | error | information | notice | warning |
severity-level}
no logging level file
{0 | emergency} System is unusable.
{1 | alert} Immediate action needed.
{2 | critical} Critical conditions.
{3 | error} Error conditions.
{4 | warning} Warning conditions.
{5 | notice} Normal but significant conditions.
{6 | information} Informational messages.
{7 | debug} Debugging messages.
Command Mode
Global configuration
Default
Logging file level is {4 | warning}
Usage
Specifying a severity-level causes messages only at that level and numerically lower levels to files.
Examples
In the following example, the user specifies that only messages of the levels error, critical, alerts, and
emergency be logged to files:
Switch(config)# logging level file 3
Related Commands
logging level module
40.69 logging level module
To set severity level, use the logging level module command in global configuration mode. To return
the logging to the default level, use the no form of this command.
Command Syntax
logging level module {alert | critical | debug | emergency | error | information | notice | warning |
severity-level}
no logging level module
{0 | emergency} System is unusable.
{1 | alert} Immediate action needed.
{2 | critical} Critical conditions.